Discover the Conveniences of Using an IP Speaker for Clearer Announcements
Discover the Conveniences of Using an IP Speaker for Clearer Announcements
Blog Article
Network PA System for medium to large-scale projects
Intro
The XC-9000 system is a fully digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system makes certain the reliable and right transmission of all data packets. Not only can it utilize existing computer networks, such as LANs or the Internet, to transfer broadcast signals, however likewise it can likewise be deployed on a devoted broadcasting network.
A single-server system can sustain up to 3000 terminals and permits for web server plunging. There are no restrictions on the concurrent program channels, achieving true full electronic broadcasting.
System Qualities
Versatile PA System Layout
The PA system architecture is simple, consisting of solution monitoring software, network microphones, network amplifiers, network audio speakers, and other devices.All equipment is connected using the TCP/IP intranet method, enabling for flexible arrangement and very easy administration of the system, with complimentary control over broadcast content, network gadgets, and areas through the network.
Comprehensive Sound Monitoring
The audio management software program consists of integrated functions for producing broadcast strategies, flexible zoning, and pre-scheduled broadcasts.It supports 24-hour programs, permitting for altering settings throughout all the time
Versatile Audio Resource Support
The system supports numerous types of audio resources for sending out alerts like online speech and BGM playback. Sound sources can come from digital music applications, CD/DVD gamers, microphones, and so on. In enhancement, the system offers varied functions of supporting numerous broadcasting attributes such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.
Emergency Alarm System Assimilation
The system has a fire alarm system feature and can be incorporated right into a fire alarm system. When the alarm main unit gets the disconcerting signals, the cable will certainly send the signal to devices, which triggers the XC-9000, sending signals to audio speakers
Users can pick to preset settings to turn on full-area or zoned alarms in emergency situations. The alarm voices been available in numerous kinds and can be modified dealing with demands. Individuals can alter language setups, upload and edit their audio sources according to precise requirements, such as intruding alarm systems, fire alarms or air aid alarms, etc.
Fire Alarm System Combination
The system has a fire alarm system feature and can be incorporated into a fire alarm system. When the alarm main device gets the startling signals, the cable will transmit the signal to devices, which sets off the XC-9000, sending signals to speakers
Individuals can pick to predetermined settings to activate full-area or zoned alarm systems in emergencies. The alarm voices come in numerous types and might be modified accommodating demands. Individuals can transform language settings, upload and modify their audio sources according to exact needs, such as intruding alarms, fire alarms or air help alarm systems, and so on.
Application Control for System Procedures
The system makes it possible for mobile application login and usage, allowing users to start broadcasts and various other procedures to licensed terminals via the web server software program, making certain a hassle-free and structured experience.
Integrated SIP Compatibility
The system not just permits SIP phones to log in, but additionally can be attached to third-party SIP web server or IPPBX, which establishes an entirely incorporated and compatible communication system with smooth assimilation right into existing systems.
Open SDK
When big project like clever park takes place, the system supplies an open SDK incorporated into third-party application systems - IP Speaker
System Framework
Main Features
Arranged Playback
The system is able to instantly broadcast according to the set up jobs as long as users publish the audio file for each period of the day to the server and produce a playback schedule.
Area Broadcasting
The system can randomly divide a couple of network devices into various areas to play specified audio programs or send out news to any type of assigned area. The volume of each tool can be remotely readjusted.
Real-time Broadcasting
The system can transmit and record radio programs or other exterior audio sources in real-time, and at the exact same time relayed them in sync.
Fire Alarm Assimilation
The system can be integrated with the smoke alarm system for control. When an emergency alarm signal is activated, it immediately turns on the emergency broadcast feature and sustains adjacent floor alarm systems. It additionally enables for hand-operated emergency situation broadcasting by clicking a solitary switch.
SIP Phone Integration
The system can be integrated with SIP servers, permitting live speech of voice broadcasting using SIP phones to send out announcements anytime and anywhere.
CCTV Assimilation
The digital gadgets such as IP POE Audio speakers adopts the global standard ONVIF protocol, which allows their voices to be transmitted Visit Website via VMS platforms. The terminals can likewise be integrated with CCTV systems for synchronized program.
Key Products
Audio Monitoring Software XC-9000
B/S design, supports cross-platform applications.
Covers traditional broadcasting system functions, enabling for dividers monitoring.
Unified monitoring of terminals within the system, seeing job condition, and batch volume change, etc.
Sustains building multi-level server architectures, deploying monitoring according to user geographical regions.
Provides SDK growth bundles for additional growth and integration with various other system platforms.
Network Paging Console XC-9038N
Power: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.
Network Paging Console XC-9037N
Power Supply: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Methods: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.
Network Horn Audio Speaker GEN-6391A03
Power Supply: DC24V/2.7 A or POE.
Interaction Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Reaction: 100Hz~ 18KHz.
Intercom: Sustained, Built-in Microphone.
Running Temperature: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.
Network Ceiling Audio Speaker GEN-6211A03
Power Supply: DC 24V/1A or POE.
Communication Procedures: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Reaction: 100Hz~ 18KHz.
Operating Temperature: -20 to 50 ° C.
Dimensions: φ213 x 165mm.
Network Wall Surface Mount Audio Speaker GEN-6011A03
Power Supply: DC24V/1A or POE.
Communication Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency click to find out more Feedback: 100Hz~ 18KHz.
Running Temperature level: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.
Network Column Audio Speaker GEN-6191A03
Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Frequency Response: 45Hz~ 18KHz.
Running Temperature: -10~ 55 ℃.
Dimensions: 296x140x130mm.
Network Sound Bridge GEN-3101A01
Power Supply: POE.
Communication Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Regularity Action: 50Hz~ 20KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 126x66x27mm.
Network Digital Amplifier XC-9508P
Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 60Hz~ 18KHz.
Operating Temperature level: -10~ 50 ℃.
Dimensions: 440x300x44mm.
Area Combining Digital Amplifier NBS-2301
Power Supply : AIR CONDITIONING 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Protocol : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Response :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Dimensions : 483x430x88mm.
IP User Interface Unit NAC-5003
Power Supply: AC100V~ 240V, 50/60Hz.
Communication Protocol: TCP/IP, UDP.
Interfaces: recommended you read 1 Ethernet port, 32 alarm inputs, 8 alarm results.
Operating Temperature: -10~ 50 ℃.
Dimensions: 483x259x44mm.
Remedy For School
Adaptable Zoning Program:
The fully network terminals can understand versatile zoning alternatives, enabling relaying notices to specific terminals or different areas ( gadgets).
Institution Bell System:
It supplies institution bell system at the beginning/ending of the class - IP PA System. Multiple circumstances can be made, including different set up program jobs according to summer/winter timetable
Emergency Alarm Assimilation
It sustains combination with emergency alarm systems, permitting smoke alarm signals to be integrated right into the PA system.
Class Sound Amplification
Terminals sustain daily applications in class scenes. They can be connected to projectors or interactive whiteboard for audio amplification.
Smart Street Lamp/Security Pole
Support SIP Method:
Integrated SIP protocol for seamless assimilation with network communication systems.
VMS Platforms Assimilation:
Integrated ONVIF method for assimilation with VMS systems.
Third-Party Integration:
Integrated In HTTP API for combination with 3rd celebration systems.
Voice Alarm Causing:
Constructed in alarm input interface for setting off voice alarms with cameras.
Service For Hotel
Area Control by Floor:
The system offers full network setups, dividing zones counting on different floorings and control over each area separately.
Fire Alarm System Integration:
The system can be integrated with smoke alarm system, allowing assimilation of emergency alarm signals into the broadcasting system.
Scheduled Broadcasting:
It sustains programmable scheduled broadcasting, permitting adaptable plans according to numerous demands.
Emergency situation Broadcasting:
It sustains emergency broadcasting for the entire location, enabling one-click emergency interaction.
Service For Factory
Area Broadcasting:
It permits relaying to any zone, assuring no interference in between various locations.
Alarm Triggering:
Terminals have various sort of interfaces, enabling to set off alarms when gotten in touch with cameras.
All Network Gadgets:
Release of fully network gadgets substantially decreases the problem of running such as inspecting devices on hazardous websites, and hence securing people and property.
The implementation of all network devices substantially lowers the trouble of operation and upkeep monitoring
Integrated SIP Phones:
The system can be incorporated with SIP phone and program alerts using SIP phones at any moment and anywhere. Two-way audio talkback between SIP phones and IP POE Speakers makes it simple for examining devices being in office or various other work environments.
The XC-9000 system is a fully electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system makes certain the right and effective transmission of all data packets. The system supports different forms of audio sources for sending out notifications like real-time speech and BGM playback. In addition, the system supplies varied functions of supporting different broadcasting attributes such as set up broadcasting, zoned broadcasting, and emergency broadcasting.
The system can be integrated with the fire alarm system for control.